{"id":12582,"date":"2023-03-28T12:44:25","date_gmt":"2023-03-28T10:44:25","guid":{"rendered":"https:\/\/www.lxdesignstudio.co\/?p=12582"},"modified":"2023-04-02T13:49:32","modified_gmt":"2023-04-02T11:49:32","slug":"simple-fire-safety-assessment-according-to-oib-rl2","status":"publish","type":"post","link":"https:\/\/lxdesignstudio.co\/de\/einfache-brandschutz-bewertung-nach-oib-rl2\/","title":{"rendered":"Brandschutzvorschriften OIB-Richtlinien 2, \u00d6sterreich"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"12582\" class=\"elementor elementor-12582\">\n\t\t\t\t\t\t<header class=\"elementor-section elementor-top-section elementor-element elementor-element-a5424f5 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"a5424f5\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-74b3d1d\" data-id=\"74b3d1d\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b474be1 elementor-widget elementor-widget-heading\" data-id=\"b474be1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Fire Safety Assessment OIB Richtlinie, Austria<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4017d57 elementor-widget elementor-widget-text-editor\" data-id=\"4017d57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><\/p>\n<p class=\"wp-block-paragraph\">Before we begin, please use the information published by OIB for the entry into force to avoid any mistakes. Click<a href=\"https:\/\/www.oib.or.at\/de\/inkrafttreten-der-oib-rl\" target=\"_blank\" rel=\"noopener\" style=\"background-color: rgb(255, 255, 255);\">&nbsp;<span style=\"font-weight: 700;\">here to download<\/span><\/a>&nbsp;OIB Richtlinie.&nbsp;<br>Please also take note of the current version of the OIB standards, which is valid in your federal state. GK 1 to GK 5 provide minor variations, particularly in the context of creating classes.<\/p>\n<p><br><\/p>\n<p><\/p>\n<p>The OIB guideline 2&#8217;s contents serve as the foundation for mapping the requirements for general-use buildings like the following:<\/p>\n<ul>\n<li>Tenements<\/li>\n<li>Office and administrative buildings, or purposes that are similar to offices.<\/li>\n<\/ul>\n<p>In addition to some unique building uses, like:<\/p>\n<ul>\n<li>Residential and agricultural structures related to agriculture and forestry<\/li>\n<li>Buildings used for kindergartens, schools, and other similar purposes<\/li>\n<li>Housing, dorms for students, and other structures with similar uses<\/li>\n<li>Sales outlets with a minimum sales area of 600m2 and a maximum of 3,000m2<\/li>\n<li>Retirement residences, retirement residences, retirement residences, and other structures with comparable uses<\/li>\n<li>Care facilities<\/li>\n<li>Hospitals<\/li>\n<li>Meeting locations<\/li>\n<li>Refuges in remote areas<\/li>\n<\/ul>\n<p>In the event of deviations from these requirements, the development of an own fire protection concept should be planned.<br>However, before one can start with the fire safety assessment of commonly used buildings, one must address the definitions in order to determine the appropriate building class for a commonly used building.<\/p>\n<p><\/p>\n<p>These definitions define the building classes (GK1 to GK5) and the concept of flight level, on the basis of which the OIB guideline 2 then makes basic statements about the choice of the building material flammability classes (Euro classes A to F) as well as the load-bearing capacity of the load-bearing components\/structures and their fire resistance classes (e.g. R 60, REI 90, etc&#8230;). <br>As the building class increases, so do the demands placed on the stairwells<\/p>\n<p><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/header>\n\t\t\t\t<main class=\"elementor-section elementor-top-section elementor-element elementor-element-3b4ec67 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3b4ec67\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c75c426\" data-id=\"c75c426\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e9c81ed elementor-widget elementor-widget-shortcode\" data-id=\"e9c81ed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\"><script async src=\"https:\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8517811674736484\"\n     crossorigin=\"anonymous\"><\/script>\n<!-- BLOG HEADER -->\n<ins class=\"adsbygoogle\"\n     style=\"display:block\"\n     data-ad-client=\"ca-pub-8517811674736484\"\n     data-ad-slot=\"8883072661\"\n     data-ad-format=\"auto\"\n     data-full-width-responsive=\"true\"><\/ins>\n<script>\n     (adsbygoogle = window.adsbygoogle || []).push({});\n<\/script><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a705a21 elementor-widget elementor-widget-text-editor\" data-id=\"a705a21\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h5>Related: <a href=\"https:\/\/www.l-designs.co\/3d-rendering-services-industry-to-tank-61-65-billion-by-2026\/\"><span style=\"color: #947600;\">3D Rendering Services Industry To Tank $61.65 Billion By 2026<\/span><\/a><\/h5>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e3dc340 elementor-widget elementor-widget-heading\" data-id=\"e3dc340\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">First step: Building classification into one of the building classes (GK 1 to GK 5)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1584c16 elementor-widget elementor-widget-text-editor\" data-id=\"1584c16\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4><span class=\"diyfeDecoration\">Building class 1 (GK 1)<\/span><\/h4>\n<p>Freestanding, on at least three sides on their own land or of traffic areas for firefighting from the outside of buildings with no more than three storeys above ground, with an escape level of not more than 7,00 m and a total of not more than 400 m\u00b2 Gross floor area of above-ground floors consisting of no more than two dwellings or one operating unit.<\/p>\n<p>\u00a0<\/p>\n<h4><span class=\"diyfeDecoration\">Building class 2 (GK 2)<\/span><\/h4>\n<p>(a) Buildings with no more than three storeys above ground and with an escape level of not more than 7,00 m out of a total of not more than 400 m\u00b2 gross floor area of above-ground floors, Geb\u00e4udeklasse GK2, mit max. 3 Gescho\u00dfen \u00fcber Niveau und max. 7m Aufenthalts- bzw. Fluchtniveau max. Bruttogescho\u00dffl\u00e4che 400m\u00b2, dargestellt als 3D-Bild eines Reihenhauses mit Satteldach<\/p>\n<p>\u00a0<\/p>\n<p>(b) Terraced houses with no more than three storeys above ground and with a escape level of not more than 7.00 m, consisting of apartments or operating units of not more than 400 m\u00b2 gross floor area of the above-ground floors, Geb\u00e4udeklasse GK2, freistehend mit max. 3 Gescho\u00dfen \u00fcber Niveau und max. 7m Aufenthalts- bzw. Fluchtniveau max. Bruttogescho\u00dffl\u00e4che 800m\u00b2, dargestellt als 3D-Bild eines Hauses mit Satteldach<\/p>\n<p>\u00a0<\/p>\n<p>(c) Freestanding, on at least three sides on their own property or from traffic areas Buildings for firefighting from outside which are exclusively residential, with no more than three storeys above ground and with an escape level not exceeding 7,00 m of a total of no more than 800 m\u00b2 gross floor area of the above-ground floors.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5a97873 elementor-widget elementor-widget-image\" data-id=\"5a97873\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1021\" height=\"649\" src=\"https:\/\/lxdesignstudio.co\/wp-content\/uploads\/2023\/03\/OIB-richtlinie-2.jpg\" class=\"attachment-large size-large wp-image-12610\" alt=\"\" srcset=\"https:\/\/lxdesignstudio.co\/wp-content\/uploads\/2023\/03\/OIB-richtlinie-2.jpg 1021w, https:\/\/lxdesignstudio.co\/wp-content\/uploads\/2023\/03\/OIB-richtlinie-2-300x191.jpg 300w, https:\/\/lxdesignstudio.co\/wp-content\/uploads\/2023\/03\/OIB-richtlinie-2-768x488.jpg 768w, https:\/\/lxdesignstudio.co\/wp-content\/uploads\/2023\/03\/OIB-richtlinie-2-18x12.jpg 18w\" sizes=\"(max-width: 1021px) 100vw, 1021px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0a29fc7 elementor-widget elementor-widget-heading\" data-id=\"0a29fc7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Building class 3 (GK 3)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fdd39db elementor-widget elementor-widget-text-editor\" data-id=\"fdd39db\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Buildings with no more than three storeys above ground and with an escape level not exceeding 7,00 m which do not belong to building classes 1 or 2 fall.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-de6bbb9 elementor-widget elementor-widget-heading\" data-id=\"de6bbb9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Building class 4 (GK 4)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-66b769e elementor-widget elementor-widget-text-editor\" data-id=\"66b769e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>(a) Buildings with no more than four storeys above ground and with an escape level of not more than 11 m, consisting of several dwellings or several operating units of no more than 400 m\u00b2 usable area of the individual apartments or operating units on the above-ground floors,<\/p>\n<p>\u00a0<\/p>\n<p>(b) buildings with no more than four storeys above ground and with an escape level of not more than 11 m, consisting of a dwelling or a dwelling or a Operating unit without limitation of the gross floor area of the above-ground floors.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fe57cd7 elementor-widget elementor-widget-heading\" data-id=\"fe57cd7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Building class 5 (GK 5)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c63e82d elementor-widget elementor-widget-text-editor\" data-id=\"c63e82d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Buildings with an escape level not exceeding 22 m which do not fall within building classes 1, 2, 3 or 4.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-652c166 elementor-widget elementor-widget-heading\" data-id=\"652c166\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">High-Rise Buildings <\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-81233d1 elementor-widget elementor-widget-text-editor\" data-id=\"81233d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>High-rise buildings are not defined in the OIB definitions. The OIB guideline 2.3 deals with fire safety in buildings with an escape level of more than 22m. Up to 32m escape level, level 1 safety stairwells are required in the buildings. Over 32m escape level Level 2 security stairwells.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bb4587f elementor-widget elementor-widget-shortcode\" data-id=\"bb4587f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\"><script async src=\"https:\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8517811674736484\"\n     crossorigin=\"anonymous\"><\/script>\n<ins class=\"adsbygoogle\"\n     style=\"display:block\"\n     data-ad-format=\"fluid\"\n     data-ad-layout-key=\"-7k+e2+2z-17-5d\"\n     data-ad-client=\"ca-pub-8517811674736484\"\n     data-ad-slot=\"5235159667\"><\/ins>\n<script>\n     (adsbygoogle = window.adsbygoogle || []).push({});\n<\/script><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-79e9572 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"79e9572\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-ed2ffe5\" data-id=\"ed2ffe5\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-79d471d elementor-widget elementor-widget-text-editor\" data-id=\"79d471d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4 style=\"text-align: center;\"><span style=\"color: #ffffff;\">Present your design project like a work of art with Us\u00a0<\/span><\/h4>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-35acef4\" data-id=\"35acef4\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f7d8b77 elementor-mobile-align-center elementor-widget elementor-widget-button\" data-id=\"f7d8b77\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/lxdesignstudio.co\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">GET YOUR QUOTAION<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1ee862 elementor-widget elementor-widget-spacer\" data-id=\"d1ee862\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24df7f0 elementor-widget elementor-widget-heading\" data-id=\"24df7f0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Second step: definition of fire safety requirements<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-edec452 elementor-widget elementor-widget-text-editor\" data-id=\"edec452\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Only on the basis of the building class now determined is it possible in a simple way to determine the basic requirements, for example for the load-bearing loads, by means of the tables integrated in the OIB guideline 2. To determine components, stairwells, building material flammability classes, etc. There are special provisions for uses, such as for accommodation establishments, kindergartens and schools, sales outlets up to 3,000m\u00b2, hospitals and nursing homes as well as Meeting places, etc. For buildings that cannot be assessed on the basis of the OIB guideline 2 due to their peculiarities or special use, a separate fire protection concept is required.<\/p>\n<p>\u00a0<\/p>\n<p>Such special buildings are:<\/p>\n<ul>\n<li>Meeting places for more than 1,000 people<\/li>\n<li>Prisons<\/li>\n<li>Sales outlets with a sales area of more than 3,000 m\u00b2 or for sales outlets with more than three openly connected floors<\/li>\n<li>Other special buildings and structures to which the requirements of this Directive do not apply by reason of their intended use or construction.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-90f5f70 elementor-widget elementor-widget-heading\" data-id=\"90f5f70\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Third step: The escape route<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4167578 elementor-widget elementor-widget-text-editor\" data-id=\"4167578\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Securing escape is one of the top priorities in fire protection. The authors of the OIB guideline 2 have finally succeeded in including a long requirement of preventive fire protection in the regulations in addition to the elementary requirement &#8211; the so-called &#8220;40-metre rule&#8221;: the (second) escape route. If the only structural escape route is not planned according to strict criteria, an alternative escape direction is required as an escape route. The flowchart can be used in the course of planning determine which specific requirements and sections\/tables from the OIB guideline 2 apply to the project.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c2ebbed elementor-widget elementor-widget-heading\" data-id=\"c2ebbed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Speaking of escape route - a small sidestep to the AstV<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ec64b3 elementor-widget elementor-widget-text-editor\" data-id=\"6ec64b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>With the entry into force of the amendment to the Workplace Ordinance in December 2017, the escape route extension (only company buildings) introduced for the first time in OIB-RL 2.1 was incorporated into the statutory regulation. and not only for company buildings (production and\/or warehouse buildings). This makes it possible to introduce longer escape routes in workplaces if certain conditions are met. (hazards only due to fire, room geometry, technical fire protection).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-59d1a96 elementor-widget elementor-widget-image\" data-id=\"59d1a96\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1023\" height=\"571\" src=\"https:\/\/lxdesignstudio.co\/wp-content\/uploads\/2023\/03\/OIB-fire-safety-assessment-2.png\" class=\"attachment-large size-large wp-image-12617\" alt=\"\" srcset=\"https:\/\/lxdesignstudio.co\/wp-content\/uploads\/2023\/03\/OIB-fire-safety-assessment-2.png 1023w, https:\/\/lxdesignstudio.co\/wp-content\/uploads\/2023\/03\/OIB-fire-safety-assessment-2-300x167.png 300w, https:\/\/lxdesignstudio.co\/wp-content\/uploads\/2023\/03\/OIB-fire-safety-assessment-2-768x429.png 768w, https:\/\/lxdesignstudio.co\/wp-content\/uploads\/2023\/03\/OIB-fire-safety-assessment-2-18x10.png 18w\" sizes=\"(max-width: 1023px) 100vw, 1023px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/main>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-d7db39c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"d7db39c\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-cdcb0e9\" data-id=\"cdcb0e9\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-66fde97 elementor-widget elementor-widget-heading\" data-id=\"66fde97\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Sub-Guidelines<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bfaed8e elementor-widget elementor-widget-text-editor\" data-id=\"bfaed8e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Sub-guidelines have been drawn up for frequently occurring building or plant types that cannot be assessed on the basis of the provisions of OIB Guideline 2. These are currently:<\/p>\n<p>\u00a0<\/p>\n<p><a href=\"https:\/\/www.oib.or.at\/de\/oib-richtlinien\/richtlinien\/2019\/oib-richtlinie-21\" target=\"_blank\" rel=\"noopener\"><b><u>OIB Guideline 2.1<\/u><\/b><\/a>&#8211; Fire protection in industrial buildings<\/p>\n<p>\u00a0<\/p>\n<p><a href=\"https:\/\/www.oib.or.at\/de\/oib-richtlinien\/richtlinien\/2019\/oib-richtlinie-22\"><span style=\"text-decoration: underline;\"><strong>OIB guideline 2.2<\/strong><\/span><\/a> &#8211; Fire protection for garages, covered parking spaces and parking decks<\/p>\n<p>\u00a0<\/p>\n<p><a href=\"https:\/\/www.oib.or.at\/de\/oib-richtlinien\/richtlinien\/2019\/oib-richtlinie-23\"><span style=\"text-decoration: underline;\"><strong>OIB guideline 2.3<\/strong><\/span><\/a> &#8211; Fire protection in buildings with an escape level of more than 22m<\/p>\n<p>\u00a0<\/p>\n<p>The requirements of the OIB regulations are rounded off by <span style=\"text-decoration: underline;\"><strong><a href=\"https:\/\/www.oib.or.at\/de\/oib-richtlinien\/richtlinien\/2019\">cited standards<\/a> <\/strong><\/span>and other technical regulations, which are listed in a separate document.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60b2d29 elementor-widget elementor-widget-shortcode\" data-id=\"60b2d29\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\"><script async src=\"https:\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8517811674736484\"\n     crossorigin=\"anonymous\"><\/script>\n<ins class=\"adsbygoogle\"\n     style=\"display:block\"\n     data-ad-format=\"fluid\"\n     data-ad-layout-key=\"-7k+e2+2z-17-5d\"\n     data-ad-client=\"ca-pub-8517811674736484\"\n     data-ad-slot=\"5235159667\"><\/ins>\n<script>\n     (adsbygoogle = window.adsbygoogle || []).push({});\n<\/script><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<header class=\"elementor-section elementor-top-section elementor-element elementor-element-d0051a5 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"d0051a5\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-cb02fb3\" data-id=\"cb02fb3\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4349c4b elementor-widget elementor-widget-text-editor\" data-id=\"4349c4b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><\/p>\n<p class=\"wp-block-paragraph\"><\/p>\n<p class=\"wp-block-paragraph\">\u00a0<\/p>\n<h3 style=\"font-size: 2.13333rem; font-style: normal;\">GET A QUOTE ON YOUR NEXT PROJECT<\/h3>\n<p style=\"font-size: 16px; font-style: normal; color: #5a5a5a; font-family: -apple-system, system-ui, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, Cantarell, 'Fira Sans', 'Droid Sans', 'Helvetica Neue', sans-serif;\"><span style=\"font-weight: 400;\">If you are interested in hiring us for your next<\/span><b>\u00a0<a href=\"https:\/\/lxdesignstudio.co\/de\/\" target=\"_blank\" rel=\"noopener\">Architectural, Interior Design<\/a><\/b>\u00a0or<span style=\"font-weight: bold;\"><a href=\"https:\/\/lxdesignstudio.co\/\">\u00a03D rendering project<\/a>\u00a0<\/span>(good call!), send your project information to<a style=\"font-weight: 400; outline: 0px;\" href=\"mailto:office@lxdesignstudio.co\"><span style=\"font-weight: bold;\">\u00a0office@lxdesignstudio.co<\/span>\u00a0<\/a>or contact us using the quote form accessible below to get yours<br \/>today to receive an offer. We&#8217;re looking forward to hearing from you.<\/p>\n<p style=\"font-size: 16px; font-style: normal; font-weight: 400; color: #5a5a5a; font-family: -apple-system, system-ui, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, Cantarell, 'Fira Sans', 'Droid Sans', 'Helvetica Neue', sans-serif;\">Each project we do for our clients is priced individually. We ask potential customers to send us their drafts \/ drawings \/ plans \/ views \/ sketches \/ pictures. Once we have this information, our team will personally review your requirements and price your project within just 5-10 minutes of you sending us your project\u00a0 information.\u00a0<\/p>\n<p style=\"font-size: 16px; font-style: normal; font-weight: 400; color: #5a5a5a; font-family: -apple-system, system-ui, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, Cantarell, 'Fira Sans', 'Droid Sans', 'Helvetica Neue', sans-serif;\">\u00a0<\/p>\n<p style=\"font-size: 16px; font-style: normal; font-weight: 400; color: #5a5a5a; font-family: -apple-system, system-ui, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen, Ubuntu, Cantarell, 'Fira Sans', 'Droid Sans', 'Helvetica Neue', sans-serif;\">#trends in architecture #Passivhaus #Passivehouse #firesafety #3Dvisualization #OIBrichtlinilie #firesafetyregulations #fireassessment\u00a0 #escaperoute\u00a0<\/p>\n<p><\/p>\n<p><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-56efaae elementor-widget elementor-widget-shortcode\" data-id=\"56efaae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">[noptin-form id=12183]<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/header>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Fire Safety Assessment OIB Richtlinie, Austria Before we begin, please use the information published by OIB for the entry into force to avoid any mistakes. Click&nbsp;here to download&nbsp;OIB Richtlinie.&nbsp;Please also take note of the current version of the OIB standards, which is valid in your federal state. GK 1 to GK 5 provide minor variations, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":12601,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_thinkrank_schema_form_data":"","_thinkrank_selected_schema_type":"","_thinkrank_additional_schemas":"","_thinkrank_canonical_url":"","_thinkrank_og_title":"Fire safety regulations OIB-Richtlinien 2, Austria - LX Design Studio","_thinkrank_og_description":"Fire Safety Assessment OIB Richtlinie, Austria\u200b. Before we begin, please use the information published by OIB for the entry into force...","_thinkrank_og_image":"https:\/\/lxdesignstudio.co\/wp-content\/uploads\/2023\/03\/OIB-fire-safety-assessment.png","_thinkrank_twitter_title":"Fire safety regulations OIB-Richtlinien 2, Austria - LX Design Studio","_thinkrank_twitter_description":"Fire Safety Assessment OIB Richtlinie, Austria\u200b. Before we begin, please use the information published by OIB for the entry into force...","_thinkrank_twitter_image":"https:\/\/lxdesignstudio.co\/wp-content\/uploads\/2023\/03\/OIB-fire-safety-assessment.png","_thinkrank_imported_from":"yoast","_thinkrank_focus_keywords":["Fire safety regulations OIB-Richtlinien 2 Austria"],"_thinkrank_focus_keyword":"Fire safety regulations OIB-Richtlinien 2 Austria","_thinkrank_robots_meta_enabled":0,"_thinkrank_robots_meta":"","_thinkrank_advanced_robots_meta":"","_thinkrank_primary_category":8,"site-sidebar-layout":"right-sidebar","site-content-layout":"plain-container","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[8],"tags":[68,52,69,66,67,54],"class_list":["post-12582","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-architecture","tag-brandschutz","tag-brandschutzbewertung","tag-fire-regulations-austria","tag-fire-safety-assessment","tag-oib-gebaudeklassen","tag-oib-richtlinien"],"_links":{"self":[{"href":"https:\/\/lxdesignstudio.co\/de\/wp-json\/wp\/v2\/posts\/12582","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lxdesignstudio.co\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lxdesignstudio.co\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/lxdesignstudio.co\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/lxdesignstudio.co\/de\/wp-json\/wp\/v2\/comments?post=12582"}],"version-history":[{"count":0,"href":"https:\/\/lxdesignstudio.co\/de\/wp-json\/wp\/v2\/posts\/12582\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lxdesignstudio.co\/de\/wp-json\/wp\/v2\/media\/12601"}],"wp:attachment":[{"href":"https:\/\/lxdesignstudio.co\/de\/wp-json\/wp\/v2\/media?parent=12582"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lxdesignstudio.co\/de\/wp-json\/wp\/v2\/categories?post=12582"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lxdesignstudio.co\/de\/wp-json\/wp\/v2\/tags?post=12582"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}